Table of Content
If you're looking to get PAT testing carried out for your commercial or domestic property, we're here to help.
Overall it is safer if a competent person makes a visual inspection than if a layman merely observes the presence of a sticker. This in turn allows testing and the interpretation of results to be de-skilled to a large extent. The inspection of the appliances can largely be carried out in-house in many organisations. This can result in cost savings and more flexibility as to exactly when a PAT is carried out.
Property Description
Many appliances can be deemed unsafe by simply looking for visual defects like damaged cables and broken casings. Every year thousands of incidents and fatal injuries are reported caused by faulty electrical appliances. These are the simple-to-use and comparatively much cheaper portable appliance testers for most businesses who will test in-house to carry out the testing and suitable for a wide range of businesses. The earth lead is connected to metal parts on both Class I and Class II appliances. For "Class I" during the earth test to prove continuity between earth pin and metal parts on the appliance. For "Class II" during the insulation test to prove the insulation between active-neutral and the metal parts of the appliance.
12V maximum, 1.5 times rated current of appliance or 25A, whichever is greater - commonly known as "type test" or "bond test". The equipment shall have a measured resistance of the protective earth circuit, or the earthing conductor of an extension cord or appliance cord set, which does not exceed 1Ω. This is a process of simply inspecting the appliance, the cable and the plug for any obvious signs of damage. Other countries have similar procedures, for example, testing of equipment according to DGUV Vorschrift 3 in Germany. Extreme temperatures, tugging, pulling and friction all cause tears, cracking and melting. When you contact your PAT tester, let them know roughly how many units need to be tested.
Equipment hot to the touch
If you catch a burnt plastic or fishy smell , this may mean something is overheating. Get in touch with an electrician straight away who will be able to find out where the smell is coming from. For example, if you have a computer with two monitors, it would be counted as six separate units to be tested.

In addition to this there are other precautions that need to be taken and these are presented in this chapter. The purpose of the test is to check that there is a good connection between the Earth pin on the plug and the case of the appliance. A good connection is defined as having a resistance of less than 0.1 ohms (or 100 milli-ohms). We’ve used Hexo to provide a pre-house purchase EHIC and post-house purchase remedial work. Customer service used to organise both was great - no patronising, just straightforward explanation of the work needed and breakdown of cost. They made it easy to organise dates and carried out the EHIC at short notice.
Damaged cords
Note the inside of the plug should be checked unless it is moulded or there is an unbroken seal covering the screws . There are many common myths about portable appliance testing - find out the key facts about the inspection and testing of portable electrical equipment here. According to PAT testing legislation, a competent person is someone who has experience or knowledge of being able to check and test appliances for safety purposes.
Then this portable appliance testing online training course will set you up with a solid foundation to become a confident electrician and help you to develop your expertise in portable appliance testing. Lightning is responsible for hundreds of injuries each year in the UK as a result of lightning strikes and the electrical surges that follow them, and therefore it is vital to meet the legal requirements for lightning protection to mitigate risk. O The ISO 9000 Quality Assurance Standard requires all companies to comply with the Health and Safety requirements, portable appliance testing is required to comply with this standard.
This comprehensive portable appliance testing online training course is the perfect way to kickstart your career in the field of portable appliance testing. This portable appliance testing online training course will give you a competitive advantage in your career, making you stand out from all other applicants and employees. It is a legal requirement for all employers and premises to ensure all appliances are safe to use. One aspect of electrical appliances that tends to cause a lot of confusion is the question "What fuse should this appliance have?".

E.g. it may not be safe to perform a leakage current test which powers up the appliance, such as a grinder, if it can not be secured to a bench; an insulation resistance test may be a safe option. At periodic intervals, the portable appliances are tested to measure that the degree of protection to ensure that it is adequate. At these intervals, a formal visual inspection is carried out and then followed by electrical testing.
These appliances should always be maintained properly and remain in good working order. Fokearn Engineering Ltd services the complete Republic of Ireland, We perform comprehensive electrical safety tests on plug top and fixed wired appliances. We are Safe Electric Registered and our technicians are City & Guilds qualified, we offer a quality PAT Testing services you can trust. As well as the visual inspection, electrical test equipment is used to check the safety of the appliance and the results are documented to minimise future risk factors. The Electricity at Work Regulations 1989 makes it your responsibility to make sure all your electrical equipment is safe to use.

You will also be able to add your new skills to your CV, enhance your career and become more competitive in your chosen industry. There are no academic entry requirements for this portable appliance testing online trainingcourse, and it is open to students of all academic backgrounds. As one of the leading course providers and most renowned e-learning specialists online, we’re dedicated to giving you the best educational experience possible. This portable appliance testing online training course is crafted by industry expert, to enable you to learn quickly and efficiently, and at your own pace and convenience. This portable appliance testing online training course isaccreditedby theCPD UK&IPHM.
Many organisations look for employees with CPD requirements, which means, that by doing this course, you would be a potential candidate in your respective field. Because PAT Testing is a regular task, often yearly, it is important to find the right contractor. A good contractor will schedule the testing well in advance and will carry out the work quickly and efficiently as well as providing a quality after-sale service. A calibration certificate should be issued to prove the PAT unit has been electrically tested. Specific microwave leakage testing was recommended for microwave ovens in the United Kingdom up until version 3 of the IET Code of Practice. A current, equal to the rated tripping current, shall be "suddenly" applied between active and protective earth and the operating time measured with maximum trip time 40 ms for Type I and 300 ms for Type II.

A leakage current test performed at rated voltage with values not exceeding 5mA for Class I appliances or 1mA for Class II appliances. This test shows the resistance offered by the earthing rods with the connection leads. Advising the user of potential danger signs can result in problems being picked up before they can result in any danger. For example, if the power cable is frayed or the plug is cracked, users need to be advised not to use the appliance and report the fault to a supervisor. This information can be put across, say by the use of a poster or in a memo. User checks are always carried out before the operation, and the results are generally not recorded unless a defect is identified.
Adequate insulation is defined as greater than 1 M ohm for Class I appliances and 2 M ohm for Class II appliances. During PAT Testing, different tests are carried out depending on the Class of equipment. If the appliance has a standard 13amp plug or a commando plug, then it can be PAT tested with a normal PAT tester.